Miller Electric

Fume Extraction

Home » Products » Fume Extraction » FILTAIR® - 2000 - 12000 Centralized Systems

FILTAIR® - 2000 - 12000 Centralized Systems

The Industrial Centralized Series are custom engineered solutions designed for multiple capture sources which require ducting and accessories to complete the system.

FILTAIR 4000
  • FILTAIR 4000
  • FILTAIR 4000 Control Panel
  • FILTAIR 4000 Filter Change
  • FILTAIR 2000 Weld Cell with Automation Hood

Miller FilTek XL Filter Technology

Miller FilTek XL Filter Technology
Miller FilTek XL Filter Technology is specifically designed for welding fumes. Miller filters outlast, out-filter, and outperform all the rest.
  • Has longer filter life - up to 2 times that of treated cellulous filters.
  • Superior filtering of up to 95% of weld fume particulates.
  • FilTek XL's surface loading filters vs. competitors depth loading filters gives Miller filters advantages that benefit you:
    • Easier and more complete filter cleaning results in longer filter life.
    • More efficient air flow thru the filter results in lower operating costs and stronger suction power for a cleaner work space.

Video: See how it works >>

Easy-Clean FilTek XL Filter

Surface-loaded filter technology allows for more effective weld fume pulse cleaning without penetration into the filter. This provides an easier filter cleaning process, while outlasting conventional cartridge filters.

Smaller Size and Fewer Filters

Smaller Size and Fewer Filters
One FilTek XL filter replaces up to three cartridge style filters increasing efficiency, reducing extractor size, and lowering operation costs.

Total Welding Solution

Providing the leading fume extractors, ducting, arms, automation hoods, accessories and industry knowledge, Miller provides the total fume extraction solution.

Up to 65% smaller size

Up to 65% smaller size
Unlike any other in the industry, our design provides up to a 65% smaller footprint versus the traditional cartridge filter collector. Not only saving space but also providing a completely packaged system with unsurpassed performance.

Quieter operation

Quieter operation
UP to 75% quieter than common cartridge style extractors.  FILTAIR 2000-12000 extrators utilize premium high efficiency motors and standard integrated silencer housing to reduce sound and make a safer, more productive work area. Note: Quietest operation is while filtering.  Pulse cleaning cycle has a higher noise level than filtering.

Maintenance Free

Maintenance Free
Premium high-efficiency motor with direct drive blower eliminates bearings and belts and ensures vibration free operation.  Located in clean air maximized life.

 
 

Models

Stock #

XMT® 350 VS ArcReach™ 907224002

XMT® 450 VS ArcReach™ 907481002

SuitCase® X-TREME™ 8VS ArcReach™ with Bernard® S-Gun™ 951588

SuitCase® X-TREME™ 8VS ArcReach™ with Bernard® Q300 Gun 951584

SuitCase® X-TREME™ 12VS ArcReach™ with Bernard® S-Gun™ 951589

SuitCase® X-TREME™ 12VS ArcReach™ with Bernard® Q300 Gun 951581

Product Literature
Spec Sheet
Brochure
FilTek XL Filter advantages
Low Profile Hood Flyer
Total Weld Fume Solutions Flyer
 
ProcessesMIG (GMAW) 
TIG (GTAW) 
Stick (SMAW) 
Flux Cored (FCAW) 
General specificationsInput Power
460 V, 3-Phase, 60 Hz
Net WeightFILTAIR™ 2000 - 1300 lb.(590 kg) FILTAIR™ 4000 - 1600 lb.(726 kg) FILTAIR™ 6000 - 2250 lb.(1021 kg) FILTAIR™ 8000 - 2900 lb.(1315 kg) FILTAIR™ 12000 - 3900 lb. (1769 kg)
Dimensions
FILTAIR 2000 – 31.2 in. 66.6 in. 83.2 in.  (792 mm) (1692 mm) (2113 mm)
FILTAIR 4000 - 31.2 in. 86.1 in. 83.2 in. (792 mm) (2187 mm) (2113 mm)
FILTAIR 6000 - 31.2 in. 117.2 in. 83.2 in. (792 mm) (2977 mm) (2113 mm)
FILTAIR 8000 – 37.2 in. 135 in. 83.2 in. (945 mm) (3429 mm) (2113 mm)
FILTAIR 12000 – 59.7 in. 120.3 in. 83.2 in. (1516 mm) (3056 mm) (2113 mm)
Filter Media
FILTAIR 2000 – 280 sq. ft (26 sq. m)
FILTAIR 4000 -  560 sq. ft (52 sq. m)
FILTAIR 6000 -  840 sq. ft (78 sq. m)
FILTAIR 8000 – 1120 sq. ft (104 sq. m)
FILTAIR 12000 – 1680 sq. ft (156 sq. m)
Nominal Airflow
FILTAIR 2000 – 960-3200 CFM (453-1510 L/sec.)
FILTAIR 4000 - 1920-5500 CFM (906-2596 L/sec.)
FILTAIR 6000 - 2880-8640 CFM (1359-4078 L/sec.)
FILTAIR 8000 – 3840-11,520 CFM (1812-5437 L/sec.)
FILTAIR 12000 – 5760-13,440 CFM (2718-6343 L/sec.)
Sound Level
72–75 dBA; peak pulse noise: 92.7 dBA
Motor
FILTAIR 2000 –  3 and 5 HP
FILTAIR 4000 -  5, 7.5 and 10 HP
FILTAIR 6000 -  10 and 15 HP
FILTAIR 8000 – 15 and 20 HP
FILTAIR 12000 – 20 and 30 HP
Number of Filters
FILTAIR 2000 –  2
FILTAIR 4000 -  4
FILTAIR 6000 -  6
FILTAIR 8000 – 8
FILTAIR 12000 – 12
ApplicationsFabrication 
Manufacturing 
Schools/Training 

Models

Stock # Manufacturer List Price US$    
  FILTAIR 2000 (3HP)  300899001 $0.00  
  FILTAIR 2000 (3HP) W/HEPA  300899002 $0.00  
  FILTAIR 2000 (5HP)  300899003 $0.00  
  FILTAIR 2000 (5HP) W/HEPA  300899004 $0.00  
  FILTAIR 4000 5HP  300900001 $0.00  
  FILTAIR 4000 5HP W/HEPA  300900002 $0.00  
  FILTAIR 4000 7.5HP  300900003 $0.00  
  FILTAIR 4000 7.5HP W/HEPA  300900004 $0.00  
  FILTAIR 4000 10HP  300900005 $0.00  
  FILTAIR 4000 10HP W/HEPA  300900006 $0.00  
  FILTAIR 6000 10HP  300901001 $0.00  
  FILTAIR 6000 10HP W/HEPA  300901002 $0.00  
  FILTAIR 6000 15HP W/HEPA  300901004 $0.00  
  FILTAIR 8000 15HP  300902001 $0.00  
  FILTAIR 8000 15HP W/HEPA  300902002 $0.00  
  FILTAIR 8000 20HP  300902003 $0.00  
  FILTAIR 8000 20HP W/HEPA  300902004 $0.00  
  FILTAIR 12000 20HP  300903001 $0.00  
  FILTAIR 12000 20HP W/HEPA  300903002 $0.00  
  FILTAIR 12000 30HP  300903003 $0.00  
  FILTAIR 12000 30HP W/HEPA  300903004 $0.00  
       

Most Popular Accessories

FILTAIR Low Profile Hood

FILTAIR Low Profile Hood

Designed for the rugged demands of automated welding operations. Hood design offers an extremely effective capture of weld fume with an efficient primary air flow capture and an exclusive secondary air path capture design. Clear, UV protected ceiling panels allow maximum light into the cell. Unique air flow offers spark abatement in the standard deflector plate and noise reduction for quiet operation. The hood's corner hooks are convenient for hanging or installing the hood on a cell or legs.

Spark Cooler

Spark Cooler

Designed to cool sparks that are generated from the welding process before they reach the Weld Fume Extractor. Its simple design is easy to install and is very efficient by using the Weld Fume Extractors air flow while maintaining maximum suction power.

Ductwork
Ductwork

Ductwork

Clamp together ducting system reduces installation time and costs, is adaptable to existing ductwork, and is reconfigurable to adapt to changing manufacturing environments.